The following tables detail the physical, power, and environmental specifications for the HP ProLiant DL385 G2 server.
Physical Specifications
The table below lists the physical specifications for the server.
| Specification |
English |
Metric |
| Width |
17.54 in |
446 mm |
| Depth |
26.01 in |
661 mm |
| Height |
3.38 in |
85.9 mm |
| Weight (max.) |
60 lb |
27.22 kg |
Power Specifications
The table below lists the power specifications for the server.
| Specification |
Value |
| Universal AC Input |
90 to 264 VAC, 47/63 Hz |
| Maximum current |
10.0 amps (100 V) |
Environmental Specifications
The table below lists the environmental specifications for the server.
| Specification – State |
English |
Metric |
| Temperature – Operating |
50° to 95° F |
10° to 35° C |
| Temperature – Non-operating |
-22° to 140° F |
-30° to 60° C |
| Humidity – Operating |
10% to 90% RH at 82. 4° F max. wet bulb (non-condensing) |
10% to 90% RH at 28° C max. wet bulb (non-condensing) |
| Humidity – Non-operating |
10% to 90% RH |
10% to 90% RH |
| Altitude – Operating |
Up to 10 000 feet |
Up to 3 050 meters |
| Altitude – Non-operating |
Up to 30 000 feet |
Up to 9 144 meters |