The following tables detail the physical, power, and environmental specifications for the HP ProLiant DL385 G2 server.

Physical Specifications

The table below lists the physical specifications for the server.

Specification English Metric
Width 17.54 in 446 mm
Depth 26.01 in 661 mm
Height 3.38 in 85.9 mm
Weight (max.) 60 lb 27.22 kg

Power Specifications

The table below lists the power specifications for the server.

Specification Value
Universal AC Input 90 to 264 VAC, 47/63 Hz
Maximum current 10.0 amps (100 V)

Environmental Specifications

The table below lists the environmental specifications for the server.

Specification – State English Metric
Temperature – Operating 50° to 95° F 10° to 35° C
Temperature – Non-operating -22° to 140° F -30° to 60° C
Humidity – Operating 10% to 90% RH at 82. 4° F max. wet bulb (non-condensing) 10% to 90% RH at 28° C max. wet bulb (non-condensing)
Humidity – Non-operating 10% to 90% RH 10% to 90% RH
Altitude – Operating Up to 10 000 feet Up to 3 050 meters
Altitude – Non-operating Up to 30 000 feet Up to 9 144 meters

The temperature specifications in this table are rated for sea level. For each rise of 305 meters (1 000 feet) in altitude, the maximum temperature drops by 1° C (1.8° F).