The following tables detail the physical, power, and environmental specifications for the Sun Fire X4100 server.

Physical Specifications

The table below lists the physical specifications for the server.

Specification English Metric
Width 17 in. 432.0 mm
Depth 24 in. 610.0 mm
Height 1.7 in. 44.0 mm
Weight (max.) 17 lbs 8.0 kg

Power Specifications

The table below lists the power specifications for the server.

Specification Value
Universal AC Input 100 to 240 VAC, 50/60 Hz
Maximum current 3.5 amps (200 VAC) 7.0 amps (100 VAC)

Environmental Specifications

The table below lists the environmental specifications for the server.

Specification – State English Metric
Temperature – Operating 41° to 95° F 5° to 35° C
Temperature – Non-operating -40° to 158° F -40° to 70° C
Humidity – Operating 10% to 90% RH (non-condensing) 10% to 90% RH (non-condensing)
Humidity – Non-operating 10% to 90% RH 10% to 90% RH
Altitude – Operating Up to 10 000 feet Up to 3 048 meters